Features

  • Light Weight and easy to install
  • Easy assembly instruction
  • Highest Specific Compression and Impact Strength
  • Low Coefficient of Friction
  • Wide Temperature Rating varies from -40 c° to 110 c° and no deformation or sagging are expected.
  • Corrosion Resistance
  • No cable Fusion
  • Low coefficient of thermal expansion
  • Non toxic

CONDUIT

GRE CONDUIT

The Complete and Low Cost System

GRE conduit is manufactured, tested, and has quality comply with both Thai and international standard – TIS2518-2557 and NEMA TC 14 part B. We offer a complete system with fitting and accessories.Our manufacturing and after sales service team has 20 years experience which can garuntee a quality of product and problem-solving shill and service at job site.

conduits1
conduits2

GRE CONDUIT

The Complete and Low Cost System

GRE conduit is manufactured, tested, and has quality comply with both Thai and international standard – TIS2518-2557 and NEMA TC 14 part B. We offer a complete system with fitting and accessories.Our manufacturing and after sales service team has 20 years experience which can garuntee a quality of product and problem-solving shill and service at job site.

3 EASY
STEPS

Assembly Instruction

No special equipment or skilled labour are required. Assembly requires no adhesives; cutting, threading or tapering; or any specialized equipment. GRE assembly is followed these 3 simple steps.

Note: In restricted working areas, silicone or similar lubricant can be applied to the spigot to ease the assembly.

Designed for these applications

  • Direct burial
  • Concrete Encasement
  • Under Bridge
  • Polerisers
  • Tunnels

STANDARD : TIS 2518-2557, NEMA TC14 – 1984, NEC Article 347

CONCRETE ENCASEMENT

Concrete encased conduit bank is suitable to install in an area which is subjected to repeat excavation
and concrete is required to provide protection from an accidental dig-in. In such cases,the concrete
would provide protection against a disruption of service and in the case of power cables,
will help to prevent electrocution.

 

Concrete encased conduit bank is suitable to install in an area
which is subjected to repeat excavation and concrete is required to provide protection from
an accidental dig-in. In such cases,the concrete would provide protection against a disruption of service and in the case of power cables, will help to prevent electrocution.

PIPE JACKING INSTALLATION

Pipe Jacking is the successful installation in heavy traffic area instead of Open-cut digging.
Regarding to the continuous service temperature of 110 ºC (230 ºF), no cracking or sagging is occurred during working. In accordance with the quick installation, this technique is consequently solved the problem of installation electrical duct bank in the heavy traffic.

Pipe Jacking is the successful installation in heavy traffic area instead of Open-cut digging. Regarding to the continuous service temperature of 110 ºC (230 ºF), no cracking or sagging is occurred during working. In accordance with the quick installation, this technique is consequently solved the problem of installation electrical duct bank in the heavy traffic.

DIRECT BURIAL INSTALLATION

Direct burial technique is available for a proper installation and that the area is not subjected to repeat digging. The advantage of this method is that it completely eliminates the need for concrete, thus saving money and the time needed to make up forms, haul away excavated soil.
Direct burial technique is available for a proper installation and that the area is not subjected to repeat digging. The advantage of this method is that it completely eliminates the need for concrete, thus saving money and the time needed to make up forms, haul away excavated soil.

ABOVE GROUND INSTALLATION

In regard to the strength and chemical resistant, low coefficient of thermal expansion and long system life with U.V. protection, GRE conduit is the best choice to install above ground system. This technique is enable to be pulled longer cable through the conduit and used fewer joints, there by reducing the overall installation costs.
In regard to the strength and chemical resistant, low coefficient of thermal expansion and long system life with U.V. protection, GRE conduit is the best choice to install above ground system. This technique is enable to be pulled longer cable through the conduit and used fewer joints, there by reducing the overall installation costs.

FITTINGS PRODUCTS

ENGINEERING SPECIFICATION

ConduitSpecification
StandardWall
HeavyWall

AFTER SALES SERVICE

AFTER SALES SERVICE

…… ดัดท่อขึ้น Riser …..

…… ดัดท่อหลบอุปสรรค …..

…… ดัดท่อแปรขบวน …..

fittings product

installation

TESTING METHOD : UNDER NEMA TC14-1984, ASTM AND UL STANDARD

  • TIGHTNESS OF JOINT TEST UNDER : UL 1684
  • Standard : No leakage at joint within  24 hours.

  • JOINT TIGHTNESS TEST at NBIA : CFZ (Observe by NBIA)


  • WATER ABSORPTION TEST UNDER : UL 1684
  • Standard : <0.25% of its weight ( 5 inch )
  • มาตรฐาน : การดูดซึมน้ำต้องน้อยกว่า 0.25% ของน้ำหนักชิ้นงาน

  • JOINT PULLOUT TEST UNDER : ASTM D 2105
  • Standard : > 453.70 kg. or 1,000 lbs.
  • มาตรฐาน: กำลังรับแรงดึงที่รอยต่อต้องไม่น้อยกว่า 453.70 กก.  หรือ  1,000  ปอนด์

  • JOINT PULLOUT TEST at NBIA : CFZ (Observe by NBIA)

  • TENSILE TEST UNDER : ASTM D 2105
  • Standard : > 62.05 MPa
  • มาตรฐาน: ต้องสามารถรับแรงดึงได้มากกว่า  62.05 MPa

  • STRIFFNESS TEST UNDER : ASTM D 2414
  • Standard : >151.7 KPa ( 5 inch )
  • มาตรฐาน: ต้องสามารถรับแรงกดจนได้มากกว่า 151.70 MPa เมื่อกดชิ้นงานลง 5%

  • FIRE RESISTANCE TEST Under : UL94
  • Standard : Not more than 75 mm./ minute.(ชิ้นงานต้องดับภายใน 75 mm./ นาที)

  • FIRE RESISTANCE TEST at TCC Factory (Observe by NBIA)

  • HEAT DISTORTION TEST (HDT) UNDER : ASTM D648
  • Standard : No deformation at 102 °C at 264 psi
  • มาตรฐาน : สามารถทนอุณหภูมิไม่น้อยกว่า 102°C ที่ระดับแรงกด 264 psi

 

  • IMPACT TEST UNDER : ASTM D 2444
  • Standard : No crack or any damage at 70 ft. lbs (5” SW type)
  • มาตรฐาน:  ต้องสามารถรับแรงกระแทกที่ระดับ  70 ft. lbs โดยไม่แตกร้าวในขนาด 5” SW type